43.How do you test reverse power trip

September 29, 2018 Posted by AK No comments
When two generators are running in parallel and one generator can carry the load, reverse power trip can be tested by load shifting using governor control. When the load has shifted sufficiently and the off loaded generator is carrying a small percentage of load, its breaker trips and fuel supply to its prime mover cuts off. This means reverse power relay has operated. The relay can be tested by simulation (using the test push button on the relay) to see if it initiates a trip signal