Recently asked questions in Kochi mmd and Class 2 Numerical solutions

Search

08 October 2018

31.Cargo hold fire detection system

October 08, 2018 Posted by AK No comments

The release mechanism of CO2 system in cargo spaces is same as that of the machinery spaces. The only difference is that the cargo spaces have a different type of fire detection system.
For detection of fire in cargo hold, a sample of air is drawn from all the cargo holds by an extractor fan.This sample of air is passed through a cabinet wherein a set of smoke sensitive sensors analyze the sample. The sensors will detect any presence of smoke in the sample. As soon as the sensor detects smoke in the sample, it activates the CO2 alarm system of the ship. A part of the sample is also discharged to the wheelhouse in order to cross-check the presence of smoke in the sample. This can be done by smelling the smoke. The sample is later vented to the air.
In order to check whether the extractor is extracting samples from the holds, a small indicator propeller is fitted, which ensures that the samples are taken.

0 comments: