Class A
- Are divisions forming bulkheads and decks that are;
- Constructed of steel or equivalent
- suitably stiffened
- Prevent passage of smoke and flame to the end of one hour standard fire test
- Insulated using non-combustible material so that average temperature on un-exposed side does not rise above 139o C and point temperature above 180o The time duration for which the bulkhead complies with this , governs its class
A-60— 60 Min
A-30— 30 Min
A-15 —15 Min
A-0 —0 Min
Class B
- These are divisions formed by bulkheads, decks, ceilings and lining
- Prevent passage of flame for first half hour of standard fire test
- Insulated so average un-exposed side temperature does not rise more than 139oC above original and no single point rises more than 225oC above original .
- B-15 -15 Min
B-0 -0 Min - Constructed of non-combustible material and all materials entering the construction are similarly non-combustible except where permitted.
Class C
- These are divisions constructed of approved non-combustible materials. Combustible veneers are allowed where they meet other criteria
- Main vertical zones Divided by Class A bulkheads and not exceeding 40m in length
Locations
Exterior boundaries of super structure and deck house enclosing accommodation and service space must be of Class A 60.
Bulkhead separating spaces in accommodation can be of A 60 to Class C
All non boundary bulkhead is of Class B or C
All non boundary bulkhead is of Class B or C