6.Fire control plan content & Location

October 04, 2018 Posted by AK No comments
Fire control plan should show all the FFA Equipments, alarm , stopping devices, there numbers,
location where they stored. It is an approved Plan by the Flag state.
Fire control plan should show clearly the following.
• (a) Control stations on each deck
• (b) The sections of the ship which are enclosed by fire resisting Bulkheads
• (c) Particulars of fire detection and fire alarms system
• (d) The sprinkler installation (fixed fire fighting system)
• (e) Fire Extinguishing appliance
• (f) Fireman’s out fit
• (g) EEBD
• (h) Ventilations closing arrangement
• (i) Ventilation fan / oil fuel Pumps / fire Pumps controls (outside E/R)
• (j) QCV remote operation position
• (k) Primary and secondary Escape routes from E/R and Accommodation
• (l) Location of International shore connections
• (m) Fire Hydrants / Hoses location
• (n) Ships particulars
• (o) Fire pumps locations
• (p) Spaces protected by fixed fire fighting system Co2 / Dry powder / Foam/ water
• (q) Location of fixed Co2 / Foam / Dry powder installation
(r) Any other fire fighting equipment with specific application

Fire plan should be fixed in prominent places such as ECR, Bridge, all the alley ways. Two
numbers outside the accommodation one in the port and the other in the stbd side(For shore fire fighters to know the location of all equipment)

Things in the fire plan box are 1.Fire control plan 2.Cargo manifest 3.Crew list