139.Air compressor not building pressure February 10, 2019 Posted by AK Motor and MEP Question & Answers No comments 1. Leakage on piping - Repair the leak. 2.Damaged compressor valve - Check and clean, or replace. 3.Wear of piston ring - Check and replace if necessary. 4.Clogged suction filter - Replace element. 5. Defective operation of unloader (magnetic valve) Email ThisBlogThis!Share to XShare to Facebook